HIMA HIMATRIX F30 010 20 (F3001020) Safety‑Related Controller
Product Description
HIMA HIMATRIX F30 010 20, belongs to the HIMatrix compact safety controller product line and is developed for distributed safety control scenarios. F3001020 supports local I/O processing and multi‑device networking, complying with safety level requirements of SIL3, PL e and Cat.4.
F3001020 is suitable for industrial sites with limited points but mandatory requirements for functional safety and fault diagnosis. It can run standalone or connect to the HIMatrix distributed network to realize multi‑point decentralized safety management and control.
Balancing compact dimension and safety performance, HIMA HIMATRIX F30 010 20 is widely applied in machinery safety, process industry and rail transit supporting projects. F3001020 drives equipment to enter predefined safe states upon fault occurrence and reduces process and equipment risks.

Technical Specifications
- Product Model: HIMATRIX F30 010 20, Part No. F3001020
- Safety Certification: SIL3 (IEC61508/IEC61511), PL e, Cat.4, ATEX Zone2 compliant
- I/O Configuration: 20 safety digital inputs, 8 safety digital outputs, with circuit diagnostic monitoring support
- Power Supply: 24VDC, voltage range 20.4‑28.8VDC
- Communication Interfaces: Ethernet switch ports, CANopen, RS485, SafeEthernet supported
- Programming Software: SILworX (Firmware V7 and above), ELOP II Factory (older firmware versions)
- Mounting: 35mm DIN rail mounting
- Operating Temperature: ‑25℃ ~ +60℃
- Protection Class: IP20, for cabinet‑internal installation
- Housing: Metal housing, vibration and shock resistant
- Functions: SOE sequence‑of‑event recording, multi‑task safety logic processing, built‑in fault self‑diagnosis, fail‑safe output
Core Advantages
- HIMA HIMATRIX F30 010 20 features complete channel circuit detection capability. Short‑circuit and wire‑break faults can be identified on input and output loops. F3001020 switches directly to safe state once abnormalities are detected to mitigate accident risks.
- Compact hardware dimension, direct DIN‑rail mounting without large‑size racks. Distributed deployment allows on‑site installation close to equipment and shortens wiring distance for field sensors and actuators.
- Multi‑protocol communication capability. F3001020 enables bidirectional data exchange with peer HIMatrix controllers and upper‑level DCS/SCADA systems to build distributed safety networks.
- Third‑party TÜV safety certified. Both hardware and logic comply with functional‑safety standards to meet compliance acceptance for domestic and overseas projects.
- Supports SOE sequence‑of‑event recording for accurate fault time‑sequence logging, facilitating subsequent fault review and troubleshooting.
Product Features
- 1oo2 safety architecture with internal dual‑channel hardware verification. Single‑channel faults will not directly disable safety functions.
- Full‑channel circuit monitoring. Digital inputs and outputs are equipped with wire‑break and short‑circuit diagnosis; fault codes can be read directly via software.
- Compatible with standalone operation and networking. F3001020 executes complete safety logic as a single unit or cooperates via HIMatrix safe Ethernet networking.
- Firmware upgradeable. Multiple programming languages including Function Block Diagram and Structured Text (ST) are supported to accommodate different engineer habits.
- LED status indicators for power, run, fault and channel status, enabling quick on‑site status judgment.
- Qualified for Ex Zone2 installation and can be fitted inside cabinets for hazardous area Division 2 applications.
Application Fields
- Process Industry: Small‑sized skid‑mounted units, wellhead control, burner management system (BMS), mini fire & gas detection, local pipeline safety interlock.
- Machine Safety: Lifting equipment, conveyor lines, presses, AGVs, robot protection stations, safety control for lifting platforms.
- Rail Transit: Level‑crossing protection, on‑board auxiliary safety units, signal auxiliary safety point control.
- Logistics & Port: Automated high‑bay warehouses, safety protection for port hoisting machinery.
- General Machinery: Complete‑set equipment safety interlock, ESD emergency shutdown sub‑units for standalone machines.
Same‑Brand Product Comparison
| Product Model | Core Positioning | I/O Scale | Key Differences |
| F3001020 (F30 010 20) | Compact Stand‑alone / Distributed Controller | 20DI+8DO | Digital‑only I/O, compact footprint, for scattered nodes with limited points, no analog channels |
| F31 Series | Extended Digital Controller | Higher DI/DO quantity | Expanded interfaces, for standalone projects with moderately more I/O points |
| F35 Series | Mixed‑signal Controller | 24DI+8AI+8DO | Built‑in analog inputs, for process scenarios requiring safe analog signal processing |
| F20 Controller | Ultra‑compact Safety Controller | Minimal I/O | Minimum physical size, for simple equipment safety protection, limited expansion capability |
| F60 Controller | Modular Large‑scale Controller | Expandable remote I/O | For medium‑to‑large‑point centralized safety systems, rack‑based architecture |
Related Compatible Products
- F3 DIO20/8 02: Remote digital input‑output module to expand I/O points for F3001020 system
- F3 AIO8/4 01: Remote mixed analog‑digital I/O module to add analog signal acquisition capacity
- F7130A: System power supply module delivering stable 24VDC for HIMatrix network units
- PADT‑2: Programming & debugging tool for on‑site program download and fault log reading for F3001020
- F2 DO8 01: Remote digital output slave module for additional safety output channels
- F2 DI16 01: Remote digital input slave module for extended safety input acquisition points
FAQ
Q:Can F3001020 be programmed directly with ELOP II Factory?
A: It depends on the firmware version. SILworX is required for firmware V7 and above; ELOP II Factory supports V6 and earlier firmware versions. Confirm firmware version during project selection.
Q:Can HIMA HIMATRIX F30 010 20 be installed in Ex Zone1 area?
A: This model is only qualified for Ex Zone2 installation. It does not meet Zone1 explosion‑proof requirements. Select alternative hardware with corresponding certification for Zone1 applications.
Q:What does channel error code 0x10 mean on F3001020?
A: 0x10 indicates channel short‑circuit fault. Inspect external sensors, actuator wiring and troubleshoot short‑circuit issues on load side.
Q:How many remote I/O modules can one F3001020 host at maximum?
A: Constrained by safe Ethernet bandwidth and safety logic cycle. Configure per manual guidelines. Unlimited stacking is not recommended. Choose F60 series for high‑point‑count projects.
Q:Does F3001020 support redundant CPU configuration?
A: Native hardware redundancy is not available for HIMatrix F30 series. Select HIMax or HIQuad X series if redundancy is required.
Q:Do I need to purchase extra cable connectors when ordering F3001020?
A: Matching terminal plugs are included in delivery. Only external power and signal cables need to be prepared on‑site.
Q:Can programs be directly interchanged between F3001020 and F3003020?
A: Hardware low‑level differences exist. Programs cannot be copied and downloaded directly. Re‑perform hardware configuration and verify I/O channel mapping.
Recommended Same‑Series Models
F20 01,
F31 03,
F35 03,
F35 012,
F60 01,
F3 DIO 20/8 02,
F3 AIO 8/4 01,
F2 DI 16 01,
F2 DO 8 01,
F7130A,
F8641,
Important Notes
- F3001020 shall only be installed inside IP20 cabinets; outdoor exposed mounting is prohibited.
- Separate wiring for safety loops and non‑safety ordinary circuits to avoid electromagnetic interference.
- Fully back‑up project programs and fault logs before firmware upgrade. Power loss is forbidden during upgrade procedure.
- Power off the unit before removing or replacing faulty modules; follow ESD anti‑static protection regulations.
- Complete safety‑loop verification for project deployment. Re‑execute safety‑function testing after hardware configuration modification.
- Do not alter hardware housing or short‑circuit internal circuits; such actions will invalidate safety certifications.
Product Tags