GE DS200TCRAG1ACC Mark V Relay Output Board | DS200TCRAG1A
Basic Information
GE DS200TCRAG1ACC is a TCRA relay output board in the DS200 series, designed for the GE Speedtronic Mark V turbine control system. Also known as DS200TCRAG1A, it receives digital logic signals from the main controller and provides isolated output via on-board relays to drive field peripheral devices. It serves as a core spare part for discrete output channels of the Mark V system. Interlock protection, alarm circuits and auxiliary equipment start/stop control for gas turbines and steam turbines rely on DS200TCRAG1ACC for signal switching.

Specifications & Parameters
Brand: GE
Model: DS200TCRAG1ACC, Alias: DS200TCRAG1A
Type: Relay Output Board
Series: Mark V Speedtronic
Quantity of Relays: 30 pluggable relays
Relay Contact Rating: 0.5A
Interfaces: 4 pcs 34pin connectors (JOR, JOS, JOT, JO), 4 pcs 12pin connectors (JS3–JS6)
Origin: USA
Compatible Control Cores: CD, QD
Matching Terminal Boards: DTBC, DTBD, TCQE
Reference Manual: GEH-6153
Product Status: Obsolete, available as surplus spare stock only

Function Description
DS200TCRAG1ACC accepts low-level logic signals sent out by the Mark V controller and converts signals through relay contacts with electrical isolation. This board does not perform logic calculation; it acts only as a signal execution channel to convert internal control signals into dry contact switch signals for external command output. Output signals from DS200TCRAG1ACC are transmitted to terminal boards and then connected to field actuators including solenoid valves, alarm horns, oil pumps and cooling fans, to realize interlock trips, audible & visual alarms and sequential start-stop of auxiliary machines.
Main Functions & Features
High-density design with 30 pluggable relays, each contact rated at 0.5A for compact channel arrangement. Multiple pin header interfaces for direct connection with Mark V rack backplane and matched terminal boards with fixed wiring layout. Compatible with CD and QD control cores, supporting mainstream Mark V hardware architecture. Individually pluggable relay modules; faulty relays can be replaced separately without removing the whole board. Dry contact output with strong & weak current isolation, minimizing interference from field loops to the main controller. No complex parameter configuration on the board; hardware jumpers are set on matching terminal boards.

Product Characteristics
Rack-mount plug-in design, fits standard Mark V I/O rack. Independent isolation for each relay loop; single channel fault will not affect other output channels massively. PCB with conformal coating, suitable for industrial sites in power plants and oil & gas projects. Sufficient channel capacity for centralized output of multiple interlock, alarm and auxiliary control points. GEH-6153 documentation covers wiring diagrams, point definitions and troubleshooting guidelines for DS200TCRAG1ACC.
Application Scenarios
Combined-cycle power plant gas turbine control systems Steam turbine unit protection & sequence control systems Turbine equipment control for oil & gas production and pipeline transmission Turbine unit interlock monitoring in industrial power stations
Purposes
Turbine emergency trip interlock output Driving of unit audible and visual alarm loops Start and stop control of lube oil pumps, cooling fans, turning gears and other auxiliary equipment Switch control of gas pipeline vent valves and solenoid valves Hard point transmission of unit status signals to upper systems

FAQ
Q1: What is the core function of DS200TCRAG1ACC?
A1: It converts digital logic signals from the Mark V turbine controller into relay contact outputs to drive external actuators, alarm devices and auxiliary equipment.
Q2: How many relays are integrated on DS200TCRAG1ACC?
A2: It comes with 30 pluggable relays, each relay contact rated at 0.5A.
Q3: Which Mark V control cores are compatible with DS200TCRAG1ACC?
A3: It supports CD control core and QD control core for Mark V.
Q4: What terminal board models match DS200TCRAG1ACC?
A4: It is compatible with DTBC, DTBD and TCQE terminal boards.
Q5: Is DS200TCRAG1ACC discontinued?
A5: Yes, OEM production has been stopped. It is supplied from surplus spare stock in the market.
Q6: Can DS200TCRAG1A and DS200TCRAG1ACC be directly replaced with each other?
A6: Yes, they are interchangeable. DS200TCRAG1A is the base model while DS200TCRAG1ACC is a hardware revision version.
Q7: In which industries and equipment is DS200TCRAG1ACC commonly used?
A7: It is widely used for gas turbines, steam turbines in power plants and turbine unit control in oil & gas industry.
Recommended GE Related Products
DS200TCQAG1A Analog I/O Board
DS200TCDAG1A Digital I/O Board
DS200SDCCG1A Drive Control Board
DS200TCQCG1BJF Analog Overflow Board
DS200TCEBG1ACE Protection Expansion Board
DS200DSFBG2A Drive Feedback Board
DS200TBQBG1ACB Sequence Allocation Board
DS200STCAG1A ARCNET Communication Board
DS200ADPAG1 Adapter Board
DS200ADMAH1A A/D Daughter Board
DS200TCEAX1A Protection Link Board
DS200UCPBG1A CPU Carrier Board
DS200ADGIG1AAA Auxiliary Interface Board
DS200TCCBG3BDC Turbine Control Board
DS200DSPCH1A Digital Signal Processing Board
Notes
DS200TCRAG1ACC is an obsolete spare part. Verify cabinet drawings, terminal board model and control core version before purchase. Relay contact rating is 0.5A. It cannot drive high-power loads directly and must work with matched terminal boards for transit. Inspect pins for bending or oxidation before installation to avoid signal loss caused by poor contact. Make sure the unit is safely shut down and related interlock loops are isolated before replacing DS200TCRAG1ACC. Do not modify hardware jumpers on terminal boards arbitrarily; jumper settings define relay channel functions. Store in dry environment to prevent relay contact oxidation caused by humidity and heavy dust.