EMERSON Ovation 5X00622G01 RTD (Resistance Temperature Detector) input module

Manufacturer: EMERSON

Product Number: 5X00622G01

Product Type: RTD input module

Place of Origin: USA

Price Range: $2000

✓ Payment Method: Telegraphic Transfer (T/T)

✓ Warranty Period: 12 months

✓ In Stock

✓ On-site Inspection Supported


Mail: plcdcs-module@foxmail.com

Phone/Wechat/Whatsapp:+86 15359254348

Note; All products on this site are special products, the market price has been fluctuating, the specific customer service offer shall prevail, because the product is a new product, the picture is not a real shot, please confirm with customer service before placing an order model and product, price and other details, the site used, new are for sale, please contact customer service communication.
The Emerson Ovation 5X00622G01 is a high-precision Resistance Temperature Detector (RTD) input module designed for the Emerson Ovation Distributed Control System (DCS). As a core component of industrial temperature monitoring, it is engineered to accurately collect, convert, and transmit temperature data from RTD sensors to the Ovation DCS, enabling real-time temperature monitoring, control, and fault diagnosis for critical industrial processes.

This module is optimized for industrial environments, featuring robust hardware design and anti-interference capabilities to ensure stable operation even in harsh conditions such as electromagnetic interference (EMI), voltage fluctuations, and wide temperature ranges. It is fully integrated with the Ovation DCS ecosystem, supporting seamless communication with Ovation controllers, human-machine interfaces (HMIs), and data analytics platforms, making it a key solution for industries requiring high-accuracy temperature measurement.

EMERSON Ovation 5X00622G01 RTD input module...jpg

Performance Specifications

2.1 Core Measurement Parameters

ParameterSpecification
Input TypeSupports standard RTD sensors: Pt100 (Platinum 100Ω), Pt1000 (Platinum 1000Ω); compatible with 2-wire, 3-wire, 4-wire RTD configurations (industry-standard for high accuracy)
Temperature Measurement Range -200°C ~ +850°C (typical for Pt100); -50°C ~ +600°C (typical for Pt1000) – covers most industrial low-to-high temperature monitoring scenarios
Measurement Accuracy±0.1°C (at 0°C, for Pt100 3-wire/4-wire); ±0.2°C (at -200°C ~ +850°C, full range) – meets Class A RTD accuracy standards (IEC 60751)
Resolution0.01°C – enables detection of tiny temperature changes for precision processes
Sampling Rate10 samples/second per channel (configurable); 16-channel simultaneous sampling (typical) – ensures real-time data capture without delay

Electrical Parameters

ParameterSpecification
Input ResistancePt100: 100Ω (0°C); Pt1000: 1000Ω (0°C) – compatible with mainstream RTD sensor models
Excitation Current1mA (constant current, per channel) – minimizes self-heating of RTD sensors (avoids measurement errors caused by sensor heating)
Isolation VoltageChannel-to-channel: ≥250V AC (rms); Channel-to-ground: ≥500V AC (rms) – prevents cross-interference between channels and protects the module from voltage surges
Power SupplyTypically +5VDC (from Ovation DCS backplane); Power consumption: ≤5W (full load, 16 channels) – low power design reduces heat generation

EMERSON Ovation 5X00622G01 RTD input module..jpg

Environmental & Mechanical Parameters 

ParameterSpecification
Operating Temperature0°C ~ +60°C (32°F ~ +140°F) – suitable for most industrial control rooms and on-site cabinets
Storage Temperature-40°C ~ +85°C (-40°F ~ +185°F) – withstands extreme temperatures during transportation and storage
Relative Humidity5% ~ 95% (non-condensing, compliant with IEC 60068-2-30) – prevents moisture damage in humid environments
Electromagnetic Compatibility (EMC)Emission: EN 61000-6-4; Immunity: EN 61000-6-2 – resists EMI from industrial equipment (e.g., motors, inverters)
Module Dimensions Standard Ovation DCS rack-mount design: Typically 160mm (L) × 80mm (W) × 220mm (H) – fits Ovation standard cabinets without additional modification
WeightApproximately 500g – lightweight for easy rack installation and load management

Communication & Compatibility 

ParameterSpecification
Communication InterfaceOvation DCS backplane (compliant with Ovation system bus protocol) – enables high-speed data transmission to Ovation controllers (up to 100Mbps)
DCS CompatibilityFully compatible with Emerson Ovation DCS versions: Ovation v3.5+, Ovation v4.0+ – supports seamless integration with existing Ovation systems
Sensor CompatibilityWorks with all IEC 60751-compliant Pt100/Pt1000 RTD sensors; supports 2-wire (for short-distance), 3-wire/4-wire (for long-distance, high-accuracy) configurations

EMERSON Ovation 5X00622G01 RTD input module.....jpg

Application Fields

3.1 Power Generation Industry

  • Thermal Power Plants: Monitors temperature of key components such as boiler tubes, turbine bearings, and generator windings. High accuracy (±0.1°C) ensures early detection of overheating risks, preventing equipment damage and unplanned outages.
  • Nuclear Power Plants: Used in safe-grade temperature monitoring (e.g., reactor coolant loops, fuel rod assemblies) – complies with nuclear industry standards (e.g., IEEE 323) for reliability and safety.
  • Renewable Energy (Wind/Solar): Tracks temperature of wind turbine gearboxes and solar inverter heat sinks, optimizing maintenance schedules based on real-time temperature data.

Oil & Gas Industry

  • Upstream (Exploration/Production): Monitors temperature of wellheads, pipelines, and downhole equipment (e.g., electric submersible pumps) – withstanding harsh on-site conditions (wide temperature, humidity) to ensure continuous operation.
  • Midstream (Transportation/Storage): Tracks temperature of crude oil/natural gas in pipelines and storage tanks, preventing wax deposition (caused by low temperatures) or vaporization (caused by high temperatures).
  • Downstream (Refining/Petrochemical): Controls temperature in distillation columns, catalytic reactors, and heat exchangers – high resolution (0.01°C) ensures precise process control, improving product quality.

Chemical & Pharmaceutical Industry

  • Chemical Processing: Monitors temperature in polymerization reactors, mixing tanks, and cooling systems – accurate temperature control (±0.2°C full range) ensures consistent chemical reactions and reduces waste.
  • Pharmaceutical Production: Complies with GMP (Good Manufacturing Practice) standards for temperature monitoring of drug synthesis, sterilization (e.g., autoclaves), and cold chain storage (e.g., vaccine refrigerators) – data traceability supports regulatory audits.

Food & Beverage Industry

  • Processing (Baking/Freezing): Controls temperature in ovens (baking bread), freezers (frozen food), and pasteurizers – high accuracy prevents undercooking or overfreezing, ensuring product safety.
  • Cold Chain Logistics: Monitors temperature of refrigerated trucks and warehouses (for dairy, meat, fruits) – real-time data transmission to Ovation HMI enables immediate intervention if temperature deviates from set ranges.

EMERSON Ovation 5X00622G01 RTD input module.jpg

Advantages & Features

High Accuracy & Reliability

  • Class A RTD Compliance: Meets IEC 60751 Class A accuracy standards, with ±0.1°C error at 0°C (3-wire/4-wire) – suitable for precision processes requiring tiny temperature variation detection.
  • Constant Current Excitation: 1mA constant current per channel minimizes RTD self-heating (a common cause of measurement errors), ensuring long-term accuracy.
  • Robust Isolation Design: Channel-to-channel and channel-to-ground isolation (≥250V AC/500V AC) prevents cross-interference and protects the module from voltage surges, reducing fault rates.

Flexible Configuration & Easy Integration

  • Multi-Wire RTD Support: Compatible with 2-wire, 3-wire, and 4-wire RTDs – 3-wire/4-wire configurations eliminate lead resistance errors (critical for long-distance sensor installation, e.g., pipeline monitoring).
  • Configurable Sampling Rate: 10 samples/second per channel (adjustable via Ovation software) – balances real-time performance and system load based on application needs.
  • Plug-and-Play with Ovation DCS: Automatically recognized by Ovation controllers after installation; no complex hardware configuration required – reduces deployment time.

Customers who purchased this product are also browsing the following products:

Emerson VE4012S2B1 KJ3102X1-BA1 12P1863X032 analog input card

Emerson Ovation 1C31194G02 valve positioner module

TRICONEX AI2361 7400210-020 processor module

Bently Nevada 330130-040-00-CN 3300 XL Extension Cable