+86 15359254348
plcdcsmodule@foxmail.com
Location: Home > Product > Alstom
Alstom

ALSTOM P14581AE6M0440J P145 RELÉ TRANSMISOR

Warranty: 365 days

Quality: Original module

Condition: New / Used

Warehouse: Spot

Delivery time: Shipped in 3 days after payment

Mail: plcdcsmodule@foxmail.com

Phone/Wechat/Whatsapp:+86 15359254348

Note; All products on this site are special products, the market price has been fluctuating, the specific customer service offer shall prevail, because the product is a new product, the picture is not a real shot, please confirm with customer service before placing an order model and product, price and other details, the site used, new are for sale, please contact customer service communication.

ALSTOM P14581AE6M0440J P145 RELÉ TRANSMISOR

ALSTOM P14581AE6M0440J belongs to the MiCOM P145 Feeder Management Relay Transmitter, an integrated measurement, control and protection IED for distribution and transmission lines. 

The ALSTOM P14581AE6M0440J integrates fault protection, data transmission, switch control, synchronism check and auto-reclose functions, suitable for overhead lines and cable feeders. This P145 relay transmitter is designed for substation feeder bays. It can independently identify faults, transmit remote signals and support local operation, and can also connect to the substation automation system for coordinated grid logic. 

The ALSTOM P14581AE6M0440J is widely used in retrofitting projects of older distribution networks, balancing protection reliability and communication expandability.

ALSTOM P14581AE6M0440J P145 RELÉ TRANSMISOR(4).jpg

Specifications & Parameters

Rated current input: 1A or 5A 

Rated voltage range: 100Vac to 120Vac 

Auxiliary supply: Wide range 24Vdc to 54Vdc 

Hardware enclosure: 60TE standard 4U rack unit, panel flush mounting 

Digital inputs: Opto-isolated type

Output contact continuous carrying current: 10A 

Communication ports: Ethernet, RS485 K-Bus; supports IEC61850, Courier protocols 

Built-in multi-language HMI, event logging, fault recording and measured value transmission output 

Operating environment: Indoor switchgear, complies with industrial relay protection EMC standards

ALSTOM P14581AE6M0440J P145 RELÉ TRANSMISOR(2).jpg

Function Description

The ALSTOM P14581AE6M0440J collects line current and voltage signals and executes overcurrent and earth fault protection algorithms. 

When a fault is triggered, it issues a trip command and transmits measured values and alarm status to the SCADA host. 

It has embedded auto-reclose logic with synchronism check, supporting synchronous closing for ring networks and tie breakers. 

Local front-panel keys enable breaker open/close control, setting viewing and signal reset. 

The device continuously transmits current, power, frequency and other measured data to provide real-time points for SCADA systems. 

GOOSE messaging is supported for inter-bay protection coordination with other IEDs in the same series.

ALSTOM P14581AE6M0440J P145 RELÉ TRANSMISOR(3).jpg

Main Functions & Features

Multi-stage overcurrent and earth fault protection, including definite-time and inverse-time characteristics 

Integrated auto-reclose, synchronism check, remote and local control 

Measured value transmission: converts primary electrical quantities into digital signals for monitoring platforms 

Large-capacity event buffer for fault sequence of events, setting changes and communication status 

Multi-protocol parallel communication; Ethernet and serial channels work independently 

Programmable logic nodes for custom interlocking and alarm logic 

Front panel with operation keys and status LEDs for convenient on-site commissioning 

Password-based hierarchical access control to prevent unauthorised setting modification

ALSTOM P14581AE6M0440J P145 RELÉ TRANSMISOR(7).jpg

Differences Between Old and New Versions

The earlier ALSTOM-branded P145 version has limited processor memory, restricted GOOSE data points and only supports the older IEC61850 revision. 

The new Agile P145 platform adopts the upgraded XCPU3 processor with expanded memory, supports IEC61850 Ed2, and adds RBAC access control and audit logging. Older P145 units have limited communication port options; new versions offer dual Ethernet, IRIG-B time synchronisation and 1588 PTP precision time synchronisation. Pin layout remains compatible. 

The ALSTOM P14581AE6M0440J can be directly drop-in replacement for retrofits without modifying secondary wiring in the cubicle. 

New firmware includes enhanced cybersecurity policies to meet modern substation network isolation requirements.

ALSTOM P14581AE6M0440J P145 RELÉ TRANSMISOR(5).jpg

Product Characteristics

The P145 relay transmitter combines protection, control and transmission in one single unit, reducing cubicle installation points. 

Opto-isolated hardware inputs reduce mal-operation risks caused by electrical interference. 

Multiple setting groups can be stored and switched for different grid operating modes. 

Fault recording captures transient waveforms to help maintenance engineers analyse root causes after incidents. 

Wide auxiliary power range ensures stable operation at sites with fluctuating DC supply. 

Built-in self-supervision; hardware faults and communication loss trigger active alarm transmission.

Advantages

One unit covers protection + transmission + control, reducing spare part SKUs and wiring costs for projects. 

Mature setting logic for the P14581AE6M0440J with proven stability across a large installed base. 

Flexible communication options compatible with legacy serial SCADA systems and new digital substation architectures. 

Drop-in replacement capability shortens retrofit cycles for existing ALSTOM MiCOM P14x installations. 

Intuitive HMI for fast commissioning and routine inspection by field technicians. 

InterMiCOM peer-to-peer communication supports distributed feeder protection schemes.

ALSTOM P14581AE6M0440J P145 RELÉ TRANSMISOR(3).jpg

Application Scenarios

Feeder protection and monitoring for urban distribution substation bays 

Internal power cables and overhead tie lines at industrial plants 

Measurement and control for PV and wind farm grid-connection feeders 

Outlet bays for mine and chemical plant on-site power stations 

Ring main unit and switching station automation retrofits 

Replacement projects for legacy substation protection relays

Intended Use

Fast tripping and isolation for phase faults and earth faults on feeders 

Continuous electrical parameter acquisition and transmission to dispatch SCADA systems 

Auto-reclose after line faults to improve power supply continuity 

Synchronism verification before tie-breaker closing to avoid out-of-sync grid impact 

Local and remote breaker control with interlock signal reception 

Fault data storage for post-incident review and grid operation optimisation

Comparison with Other Models in the Same Series

P141: Basic feeder protection only, no auto-reclose or synchronism check, suitable for simple radial networks 

P142: Adds auto-reclose, without synchronism check, mainly for single-source feeders 

P143: Equipped with auto-reclose and synchronism check, simplified front-panel controls 

ALSTOM P14581AE6M0440J (MiCOM P145): Full set of auto-reclose, synchronism check, enhanced HMI and transmission functions. Ideal for tie lines, ring networks and bays requiring frequent synchronised switching. 

The P145 provides more programmable logic resources and larger event storage capacity than earlier models.

Related Compatible Products

MiCOM Px40 communication management units: aggregate signals from multiple relays for dispatch forwarding 

MiCOM P890 time synchronisation units: supply IRIG-B time signals 

MiCOM P030 test interface module: on-site setting download and fault record retrieval 

MiCOM P14x series compatible current transformers and voltage transformers 

MiCOM C264 remote gateway: protocol conversion for legacy SCADA systems

FAQ

Q: Can ALSTOM P14581AE6M0440J directly replace old AREVA P145 devices?

A: Pinout and mounting dimensions are compatible, secondary wiring generally remains unchanged. Please verify communication protocol revision and protection settings.

Q: What is the typical latency of measured value transmission for the P145 relay transmitter?

A: Standard electrical measurement refresh cycle is in the order of tens of milliseconds, meeting SCADA acquisition requirements for distribution networks. Fault messages are prioritised for transmission.

Q: Which suffix codes need to be confirmed when ordering ALSTOM P14581AE6M0440J?

A: Enclosure type, auxiliary supply voltage, communication protocol, I/O quantity and firmware feature options.

Q: What time synchronisation methods does this P145 support?

A: IRIG-B hard-wired time sync, SNTP network time sync. New hardware variants support 1588 PTP precision time synchronisation.

Q: Can ALSTOM P14581AE6M0440J be used for motor protection bays?

A: This device is designed for feeder protection. It lacks dedicated motor differential and locked-rotor protection functions. MiCOM P24 series is preferred for motor applications.

Q: Will protection functions stop if the relay loses communication?

A: Protection logic runs independently of communication links. Loss of communication does not affect overcurrent and earth fault tripping.

Q: Can the auto-reclose count and time intervals of the P145 be customised?

A: Reclose attempts, blocking conditions and time delays are fully configurable in the setting menu.

Q: What software tools are required for on-site commissioning after receiving ALSTOM P14581AE6M0440J?

A: MiCOM S1 software for setting configuration, fault record extraction and firmware upgrade, via serial cable or Ethernet commissioning line.

Recommended Products in the Same Series

MiCOM P141 Feeder Management Relay 

MiCOM P142 Feeder Management Relay with Auto-Reclose 

MiCOM P143 Feeder Management Relay with Auto-Reclose & Synchronism Check 

MiCOM P241 Motor Protection Relay 

MiCOM P242 Rotating Machinery Protection Relay 

MiCOM P441 Distance Protection Relay 

MiCOM P442 Line Distance Protection IED 

MiCOM P543 Fibre Differential Protection Relay 

MiCOM P642 Transformer Protection Relay 

MiCOM P741 Busbar Protection Relay 

MiCOM C264 Remote Gateway 

MiCOM P890 Time Synchronisation Unit 

MiCOM P030 Test Interface Module 

MiCOM P132 Compact Feeder Protection Relay 

MiCOM P14N Next-Generation Feeder Management IED

Notes

Confirm full part number suffix before placing orders. Different suffixes correspond to different I/O counts, communication and hardware options; mismatched variants may fail to meet bay requirements. Install away from high-power contactors, variable frequency drives and other strong interference sources. Check auxiliary supply voltage before power-on commissioning to prevent overvoltage damage to internal boards. Save and back up setting files after modification. For GOOSE inter-device coordination, unify substation VLAN and control block configurations. For long-term idle P145 relay transmitters, perform periodic power-on inspections to avoid internal capacitor ageing.

Product Tags

ALSTOM P14581AE6M0440J, P145 relay transmitter, MiCOM P145, feeder protection relay, feeder management IED, relay transmitter, distribution protection device, line protection and measurement device, MiCOM P14x series, substation protection spare parts