+86 15359254348
plcdcsmodule@foxmail.com
Location: Home > Product > Other
Other

AMETEK 305010901S Moisture Generator 50 ppmv For 3050-OLV 3050-RM Analyzers

  • Brand:AMETEK
  • Model:305010901S
  • Type:Moisture Generator / Cal Moisture Generator
  • Nominal moisture output:50 ppmv
  • Compatible analyzers:3050‑OLV, 3050‑RM
  • Product type:FRU field replaceable unit
  • Traceability:NIST traceable permeation device
  • Application:On‑line verification & calibration for trace moisture analyzer


Mail: plcdcsmodule@foxmail.com

Phone/Wechat/Whatsapp:+86 15359254348

Note; All products on this site are special products, the market price has been fluctuating, the specific customer service offer shall prevail, because the product is a new product, the picture is not a real shot, please confirm with customer service before placing an order model and product, price and other details, the site used, new are for sale, please contact customer service communication.

AMETEK 305010901S Moisture Generator 50 ppmv


Overview

The AMETEK 305010901S moisture generator delivers stable 50 ppmv moisture standard gas. It is a field-replaceable component for the 3050 series moisture analyzers, paired with 3050‑OLV and 3050‑RM to perform QCM sensor calibration and online verification.

Adopting the permeation method, AMETEK 305010901S generates fixed-concentration moisture to provide traceable reference gas for trace moisture measurement instruments. It enables instrument self-verification in natural gas, specialty gas and chemical gas sampling loops, so sensor drift can be detected in a timely manner.

This unit uses NIST-traceable permeation elements with consistent concentration output. It supports direct field replacement without complex tooling.

AMETEK 305010901S Moisture Generator 50 ppmv For 3050-OLV 3050-RM Analyzers(2).jpg

Specifications

  • Brand: AMETEK
  • Model: 305010901S
  • Product Type: Moisture Generator, Calibration Moisture Generator
  • Nominal Moisture Output: 50 ppmv
  • Compatible Analyzers: 3050‑OLV, 3050‑RM
  • Component Type: FRU (Field Replaceable Unit)
  • Traceability Standard: NIST traceable permeation element
  • Application: Online verification and calibration for trace moisture analyzers\

AMETEK 305010901S Moisture Generator 50 ppmv For 3050-OLV 3050-RM Analyzers(1).jpg

Function Description

The AMETEK 305010901S continuously generates stable 50 ppmv moisture reference gas and feeds it into the analyzer sensor gas path.

The analyzer compares the measured sensor reading against the standard moisture concentration from 305010901S to identify sensor drift and complete online validation. If the verification result exceeds the allowable tolerance, maintenance or sensor replacement is required.

The full verification routine is built inside the analyzer. Online operation is supported without shutting down or disassembling the whole detection system.

Key Functions & Features

  • Generates fixed 50 ppmv standard moisture gas for trace water analyzer calibration
  • NIST-traceable permeation construction to guarantee reliable moisture concentration data
  • FRU modular design for fast field replacement
  • Engineered exclusively for 3050‑OLV and 3050‑RM analyzers
  • Permeation generation principle; no extra maintenance within service life
  • Consistent output, ideal for regular periodic verification

Product Characteristics

  • Permeation moisture generation technology with high output repeatability
  • Fixed 50 ppmv output, matching common trace water calibration requirements
  • Independent modular component; replace separately on failure to cut maintenance cost
  • Gas path matches original analyzer chamber for simple installation and connection
  • Complete concentration traceability chain to meet compliance documentation for industrial testing

AMETEK 305010901S Moisture Generator 50 ppmv For 3050-OLV 3050-RM Analyzers(3).jpg

AMETEK 305010901S Moisture Generator 50 ppmv For 3050-OLV 3050-RM Analyzers(4).jpg

Application Scenarios

  • Online trace moisture monitoring for natural gas transmission pipelines
  • Moisture detection loops for petrochemical process gas
  • Moisture monitoring during specialty gas and high-purity gas production
  • Continuous analysis systems for industrial gas quality
  • Periodic calibration stations for analyzers in gas processing plants

Purposes

  • Supply standard moisture gas for 3050‑OLV and 3050‑RM trace moisture analyzers to complete online sensor verification
  • Regularly check QCM sensor health and detect drift in advance
  • Satisfy traceability requirements for calibration in industrial gas testing projects
  • Replace external calibration gas cylinders to realize built-in auto-calibration of the analyzer

FAQ

Q: Can AMETEK 305010901S work with moisture analyzers from other brands?
A: No. The structure and gas path of 305010901S are custom-made for 3050‑OLV and 3050‑RM. It is not compatible with instruments of other brands.

Q: What information should be confirmed when ordering 305010901S?
A: Confirm the onsite analyzer model, required moisture output concentration, original spare part number and process gas medium.

Q: Does the 50 ppmv moisture output of 305010901S come with traceable certification?
A: Yes. This moisture generator adopts NIST-traceable permeation elements. Concentration data is traceable to pass audit and inspection.

Q: Do professional tools need to install 305010901S?
A: As a FRU field replaceable unit, it can be replaced with common hand tools. No dedicated calibration equipment is needed.

Q: Can 305010901S be used on other models within the 3050 series?
A: No. It only fits 3050‑OLV and 3050‑RM. Other 3050 series analyzers require moisture generators with corresponding part numbers.

Q: Does 305010901S require periodic recalibration during use?
A: No extra calibration is needed within its design service life. Replace the assembly directly when the analyzer triggers an abnormal alarm.

Q: Is 305010901S suitable for offline laboratory calibration?
A: It is designed as a built-in online verification component for analyzers. It is optimized for continuous online monitoring and not recommended for standalone offline calibration.

Q: What does an alarm from 305010901S indicate?
A: An alarm usually means the permeation element has reached the end of service life and output concentration deviates from the standard value. A new 305010901S needs to be installed.