+86 15359254348
plcdcsmodule@foxmail.com
Location: Home > Product > Emerson/Ovation
Emerson/Ovation

EMERSON VE4003S2B10 16-Channel 4-Wire AI Terminal Block for Series 2 Plus

  • Brand: Emerson
  • Model: VE4003S2B10
  • Product Name: 16-Channel 4-Wire AI Terminal Block
  • Series: DeltaV Series 2 Plus
  • Signal Type: 4-20mA Analog Input
  • Channel Count: 16 Channels, 4-Wire
  • Protocol: HART Pass-through supported
  • System: DeltaV M-series Traditional I/O
  • Feature: Field wiring termination for analog transmitters


Mail: plcdcsmodule@foxmail.com

Phone/Wechat/Whatsapp:+86 15359254348

Note; All products on this site are special products, the market price has been fluctuating, the specific customer service offer shall prevail, because the product is a new product, the picture is not a real shot, please confirm with customer service before placing an order model and product, price and other details, the site used, new are for sale, please contact customer service communication.

VE4003S2B10 16‑Channel 4‑Wire AI Terminal Block for Series 2 Plus


VE4003S2B10 is a dedicated 16‑channel 4‑wire analog input terminal block for Emerson DeltaV M‑series Traditional I/O subsystem. It is designed exclusively for AI Plus 16‑channel 4‑20mA HART I/O card. VE4003S2B10 acts as signal transition hardware between field 4‑wire transmitters and I/O cards. Pre‑wiring can be completed on cabinet side before I/O card installation. Hot‑swap of I/O card is allowed without field wiring modification. VE4003S2B10 adopts unique keying mechanism to prevent mismatched card insertion. Combined with M‑series I/O carrier, VE4003S2B10 establishes complete analog input interface for DeltaV distributed control system.

EMERSON VE4003S2B10 16-Channel 4-Wire AI Terminal Block for Series 2 Plus.jpg

Product Parameters and Physical Specifications


Channel count:16 channels for 4‑wire 4‑20mA HART analog input signals

Card keying position:A6

Supported device: externally powered 4‑wire analog /HART transmitters

Isolation: per‑channel optical isolation, factory tested 1000V DC (follow matched AI Plus card)

HART capability: HART pass‑through for AMS Device Manager

Hardware platform:DeltaV M‑series Traditional I/O

Minimum software requirement: DeltaV v13.3.1 or higher

Environmental Specifications

Operating temperature:‑40℃ ~70℃

Storage temperature:‑40℃ ~85℃

Relative humidity: 5‑95% non‑condensing

Airborne contaminant:ISA‑S71.04‑1985 Class G3 with conformal coating

Ingress protection:IP20

Shock:10g half‑sine wave for 11ms

Vibration:1mm peak‑to‑peak (5‑16Hz),0.5g (16‑150Hz)

Physical Specifications

Mounting: DIN rail installation onto M‑series I/O carrier

Dimension: H 10.7cm, W4.1cm, Depth10.5cm

Connection type:screw terminal

Installation requirement: must work together with M‑series carrier, cannot operate standalone

Core Advantages

  1. Support pre‑construction field wiring. All field cables can be terminated on VE4003S2B10 in advance. I/O cards can be fitted later during commissioning phase, shorten site work cycle and avoid card damage during construction period.
  2. Unique A6 key lock mechanism. VE4003S2B10 only accepts A6 key position AI Plus 16‑channel card, avoid human error of wrong card replacement during maintenance work.
  3. Native support for external powered 4‑wire transmitters. Field power is supplied from external source instead of internal I/O card loop, deliver stable signal acquisition for high‑power 4‑wire smart instruments.
  4. Full HART protocol pass‑through, preserve HART digital message without attenuation. Transmitter diagnostic data and parameter can be retrieved by DeltaV and AMS device management platform.
  5. Rugged industrial environment adaptability, G3 conformal coating and wide operating temperature range. It meets hazardous area Zone2 installation requirement for petro‑chemical plants and offshore facilities.

Product Features

VE4003S2B10 is an I/O interface component. Full I/O unit requires pairing with AI Plus 16‑channel 4‑20mA HART card, it cannot run independently.

HART pass‑through function, typical HART scan time for each enabled channel ranges 600‑800ms.

Field pre‑wiring is allowed. I/O card supports hot‑swap under power within safe non‑hazardous area.

This simplex terminal block does not support redundant I/O pair installation. For 1:1 redundancy application, select VE4033S2B10 redundant terminal block.

Certifications: CE, FM, CSA, ATEX, IEC‑Ex, marine IACS E10 for offshore project deployment.

Screw type terminals accept standard stranded and solid signal cables.

Application Scenarios

Petro‑chemical DCS control system for 4‑wire HART pressure, flow and temperature transmitters;

Thermal power plant for externally powered analog instrument signal collection;

Pharmaceutical automation system for mass 4‑wire smart instrument signal termination;

Large‑scale water treatment plant DeltaV DCS cabinet analog signal acquisition;

Off‑shore platform and marine automation control with DeltaV M‑series hardware;

Phased‑rollout upgrade projects, which require pre‑wiring before I/O hardware commissioning;

Control cabinet located in Zone2 /Class I Div2 hazardous locations.

Comparison with Similar Emerson Products

ModelVE4003S2B10VE4003S2B9VE4033S2B10VE4003S2B1
Channel1616168
Supported transmitter4‑wire2‑wire4‑wire (redundant)8‑ch 2/4 wire compatible
Redundancy supportNoNoYesAvailable with redundant terminal
Matched cardAI Plus16CHAI Plus16CHAI Plus16CHStandard 8CH AI HART
Minimum softwarev13.3.1v13.3.1v13.3.1v10.3.1

VE4003S2B9 is 16‑channel 2‑wire AI terminal block for two‑wire field transmitters, not suitable for externally‑fed 4‑wire instruments. VE4033S2B10 is redundant counterpart of VE4003S2B10, applied for critical control loops requiring 1:1 I/O redundancy. VE4003S2B1 is legacy 8‑channel terminal block and cannot work with 16‑channel Plus series I/O hardware.

Compatible Part Numbers

Direct matched hardware: AI Plus,16‑Channel,4‑20mA,HART Series2 Plus I/O Card

Compatible carrier: M‑series horizontal carrier, VerticalPlus carrier

Redundant replacement terminal block: VE4033S2B10 Redundant 16‑Channel 2‑ &4‑Wire AI Terminal Block for Series2 Plus

Mass termination alternative: VE4003S2B11,48‑pin AI Mass Termination Block for Series2 Plus

Field power supply: M‑series bulk AC‑to‑24VDC power supply

Supported controller: MQ,MX,PK M‑series controllers

Spare fuse: KJ4010X1‑BC1, 2A 250V fuse

Module hold‑down screw: KJ4010X1‑BP2

Sourcing & Selection Guidance

  1. Confirm I/O card model. VE4003S2B10 is only compatible with AI Plus 16‑channel card. Standard 8‑channel AI card cannot pair with VE4003S2B10.
  2. Confirm field transmitter wiring type. Select VE4003S2B9 for 2‑wire transmitters; choose VE4033S2B10 if I/O redundancy is required.
  3. Check DeltaV software revision. VE4003S2B10 requires system software v13.3.1 or newer. Older firmware cannot recognize Plus‑series I/O interface.
  4. Verify carrier hardware: VE4003S2B10 fits M‑series carrier only. Physical incompatibility exists with S‑series carrier.
  5. For mass‑termination cabinet layout, replace VE4003S2B10 with 48‑pin mass terminal VE4003S2B11.

Pitfall Reminders & After‑sales Notes

Pitfall1: VE4003S2B10 is terminal block only, without I/O card. Many orders only place VE4003S2B10 and miss AI Plus card, leading to no signal acquisition on‑site.

Pitfall2: VE4003S2B10 cannot mount onto S‑series carrier. Never mix M‑series and S‑series I/O carrier hardware.

Pitfall3: Software version must be v13.3.1 or above for Plus‑series I/O hardware support.

Pitfall4: No built‑in channel fuse inside VE4003S2B10. External fuse is required for loop protection, or select mass‑termination solution.

Pitfall5: For hazardous area installation, strictly follow Zone2 installation manual. Hot‑swap is forbidden in explosive hazardous zones.

After‑sales: For hardware fault check carrier condition, software version and card keying match status first. For wiring issue, verify screw torque. Provide full part number VE4003S2B10 for spare‑part application, confirm Series2 Plus hardware revision.

Frequently Asked Questions

Q: Can VE4003S2B10 work standalone without I/O card?

A: No. VE4003S2B10 is terminal hardware only. Complete I/O interface requires both VE4003S2B10 terminal block and AI Plus 16‑channel I/O card. Analog input cannot be captured without corresponding I/O card.

Q: Can VE4003S2B10 connect with 2‑wire transmitters?

A: Not recommended. VE4003S2B10 is optimized for externally powered 4‑wire transmitters. Select VE4003S2B9 terminal block for 2‑wire field instruments.

Q: Is VE4003S2B10 compatible with DeltaV v12 software?

A: Not supported. VE4003S2B10 belongs to Plus‑series I/O family, minimum required DeltaV software version is v13.3.1.

Q: What is difference between VE4003S2B10 and VE4033S2B10?

A: VE4003S2B10 is simplex (non‑redundant) terminal block. VE4033S2B10 is redundant terminal block which accepts dual AI Plus cards to achieve 1:1 I/O redundancy for critical process loops.

Q: Can VE4003S2B10 install on S‑series I/O carrier?

A: Physically incompatible. VE4003S2B10 supports M‑series I/O carrier only. M‑series and S‑series carriers cannot be interchanged.

Q: Does VE4003S2B10 support HART communication? Is extra hardware needed?

A: HART pass‑through is built‑in without extra hardware requirement. Just enable HART function for relevant channel inside DeltaV software to access transmitter diagnostic and HART variables.

Q: Does VE4003S2B10 terminal block integrate channel fuses?

A: VE4003S2B10 does not contain internal fuses. External fuse component must be added for circuit protection. Choose mass‑termination blocks for fused layout.

Q: If I already own VE4003S2B10, can I just add a second AI Plus card to implement I/O redundancy later?

A: It cannot be done this way. Simplex VE4003S2B10 hardware cannot hold dual I/O cards. Terminal block must be replaced with VE4033S2B10 redundant terminal block before adding secondary AI Plus card.

Recommended Emerson Part Numbers

VE4003S2B9,16‑Channel 2‑Wire AI Terminal Block for Series 2 Plus

VE4033S2B10,Redundant 16‑Channel 2‑ & 4‑Wire AI Terminal Block for Series 2 Plus

VE4003S2B11,48‑pin AI Mass Termination Block for Series 2 Plus

VE4005S2B4,16‑Channel AO Terminal Block for Series 2 Plus

VE4031S2T2B6,Redundant32‑Channel DI Terminal Block for Series 2 Plus

VE4002S2T2B8,32‑Channel DO Terminal Block for Series 2 Plus

VE4003S2B1,8‑Channel Standard I/O Termination Block

VE4003S4B1,8‑Channels Thermocouple mV Standard I/O Termination Block

VE4003S6B1,RTD 8‑Channel Resistant Temperature Device Terminal Block

VE4001S2T2B6,32‑Channel DI Terminal Block for Series 2 Plus

VE4035S2B4,Redundant 16‑Channel AO Terminal Block for Series 2 Plus

VE4053S2B11,48‑pin AI Mass Termination Block including 16‑channel Analog Mass Connection Boards

Important Notes

  1. VE4003S2B10 is terminal assembly only. Make sure corresponding AI Plus I/O card part number is included in purchasing list.
  2. Separate field power circuit and signal circuit for 4‑wire transmitters. Never connect external power supply into signal terminals, hardware damage will occur.
  3. A6 keying position of VE4003S2B10 cannot be modified. Forcing unmatched I/O card insertion causes permanent mechanical damage.
  4. Long‑term continuous operation under maximum high ambient temperature shortens service life of I/O assembly. Ensure cabinet ventilation and heat dissipation.
  5. Hot‑swap I/O card operation applies to safe non‑hazardous location only. Power‑off procedure is mandatory for hazardous Zone2 environment following installation guideline.
  6. HART communication performance relates to field cable length, wiring must comply with DeltaV official HART wiring specification.

Product Tags

VE4003S2B10,16‑Channel 4‑Wire AI Terminal Block for Series 2 Plus,DeltaV M‑series Traditional I/O,Emerson terminal block,DeltaV DCS termination,4‑wire analog input terminal block,16‑channel AI terminal,DeltaV AI Plus matching terminal,4‑20mA HART terminal block,DCS I/O termination block